20 amp 4-Way Contactor RT
This unit will run up to 20 amps of lighting using a heavy-duty contactor. Its operation is 'on/off' only and is timed using a built-in mechanical (analogue) timer.
The unit is four-way, having two switched double socket face-plates mounted on the front.
The unit is wall mountable and must be hard-wired to a fused consumer unit.
- 20 Amps of contact switching.
- Requires hard wiring only.
- On/off operation.
-
2 year guarantee.
|
A guide for working out which control unit is required to switch a set number of lights on and off.
Match the switching load to the correct control unit. Running currents for Maxibright Compact power packs are as follows: |
|
Sodium power pack |
Compact |
|
250w |
1.25 amps |
|
400w |
2 amps |
|
600w |
3 amps |
|
1000w |
5 amps |
|
For example, 2 x 1000w sodium power packs = 10 amps running current (switching load), so a 10 amp control unit should be selected. When a four-gang socket is used the maximum load per socket is 13 amps each. |